Tel Number
180-3717-8440
Model:KJ-1200T-V50
Description:
This vertical fluidized bed CVD system is specially designed for CVD experiments on powder surface deposition.
Vertical openable structure. The double-layer shell is a vertically openable structure, making it easy to pick up and place the furnace tube. It is equipped with an air cooling system to keep the temperature of the furnace shell within a safe range.
Multi-stage intelligent PID program temperature control. The temperature control system adopts PID method, and multiple "time-temperature curves" can be set at will, and 30 steps can be programmed.
Excellent dynamic sealing system. Stainless steel metal flange, with valves and related interfaces, easy to disassemble and assemble, can be vacuumed, and can connect two air sources to slightly positive pressure at the same time
Vertical fluidized bed tube furnace part | |
Model | KJ-1200T-V50 |
Heating zone length | 400mm |
Furnace tube size | diameter 50*900mm |
Furnace tube material | High-purity quartz tube with built-in 0.2mm quartz porous plate (customized) |
Working temperature | ≦1100℃ |
Max.temperature | 1200℃ |
Temperature measuring element | K type thermocouple temperature measurement |
Temperature Control System | Intelligent 30-segment PID microcomputer programmable automatic control and automatic tuning function |
Temperature control accuracy | ±1℃ |
Temperature control protection | With over-temperature and burnout protection function |
Heating rate | 0-20ºC/min |
Heating element | Alloy resistance wire |
Operating Voltage | AC 220V single phase 50HZ |
Maximum power | 3KW |
Furnace material | Polycrystalline fiber furnace material is used, which has good thermal insulation performance, high reflectivity and balanced temperature field. |
Flange | Stainless steel vacuum flange, easy to disassemble |
Sealing system | The furnace tube and flange are sealed by O-ring extrusion, which is easy to remove, can be removed repeatedly, and has good air tightness. |
fluidized area | 1. The reaction gas passes through the reaction zone evenly 2. The solid particles are suspended in the heating zone by the introduced gas. 3. The furnace body is designed to be open. When the experiment is completed, the furnace body can be opened, the quartz tube taken out, and the reacted particles taken out. Note: When gas is introduced to suspend sample particles, the particles may pass through the heating zone because the gas flow is too large. Therefore, the gas flow must be adjusted according to the size of the particles during the experiment. |
Shell structure | Double-layer shell structure with air cooling system, open type |
Furnace structure | vertical structure |
Furnace shell temperature | ≤45℃ |
Measurement and control equipment section | |
Name | Two-way mass flow meter |
Gas line | Second line |
flow control | Digital display, each gas channel contains a needle valve for individual control |
Link method | Double ferrule connector |
flow meter | Mass flowmeter |
Flow range | MFC1:N2 0-10SLM MFC2:CO2 0-10SLM |
Mixed air | Contains a precision air mixing tank |
Power supply | 220V 50HZ |
Working temperature | 5℃-45℃ |
Standard accessories | One set of main unit, 1 pair of high-sealing flanges, 1 quartz tube, 4 sealing rings, 1 pair of high-temperature gloves, 1 crucible hook, 1 flange hex wrench, 1 warranty card instruction |
Tel Number
180-3717-8440
web@kejiafurnace.com